14.55.380 Continuity.
Section R311.7.8.4, Continuity, is hereby deleted in its entirety and the following provisions shall be substituted therefor:
Handrails for stairways shall be continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than 1 1/2 inch (38 mm) between the wall and the handrails.
Exceptions:
1. Handrails shall be permitted to be interrupted by a newel post at the turn.
2. The use of a volute, turnout, starting easing or starting newel shall be allowed over the lowest tread.
3. Where walls are non-continuous, alternative non-continuous handrails may be approved by the building official on a case-by-case basis.
(Ord. 20467 § 21, 12-5-23.)